Home / Services / Switchboard upgrades
Ceramic rewireable fuses on an older switchboard awaiting replacement
Switchboard upgrades

Switchboard upgrades in the Eastern Suburbs

Rewireable fuses in a terrace hallway, a unit board that trips when the oven and the heater run together, a meter box crusted with salt — that’s a board that has done its time.

Licence 487170CNSW electrical contractor
Fully insuredPublic liability
Local to the Eastern SuburbsOn the road here daily

When a switchboard is due for replacement

One of these is worth a look. Two or more and it’s usually time to plan the change.

Ceramic rewireable fuses

White porcelain carriers with a strand of fuse wire across them. Plenty of terraces and inter-war flats still run on these. They protect the cable, not the person, and safety switches can’t be added to them — the board has to change.

Call 0411 498 916

No safety switches (RCDs)

A safety switch disconnects in roughly 30 milliseconds when current leaks to earth, which is usually what happens when it’s leaking through someone. Any new or altered circuit needs that protection, so a board without it tends to stall a renovation before it starts.

Call 0411 498 916

Breakers trip when several things run at once

Normally the board isn’t faulty, it’s outnumbered. Wiring planned around a few lights and a fridge is now feeding a heat pump, an induction cooktop and a dryer. The answer is more circuits, shared out properly — never a heavier fuse.

Call 0411 498 916

No spare positions left

Every way on the board is used. In apartments and terraces with small original boards, this is the thing that most often stops an EV charger or induction cooktop going in.

Call 0411 498 916

Corrosion in the meter box or board

Green or white crust on terminals, rust coming through the enclosure, a door that no longer seals. Near the beaches, salt air finds its way into external meter boxes and works on every connection inside — loose, corroded connections are where heat starts.

Call 0411 498 916

Buzzing, warmth or a burning smell at the board

A loose connection is arcing and making heat inside a box full of plastic and cable. Of everything on this list, this is the one that can’t wait for a convenient week.

Turn it off at the board and call 0411 498 916

Scorching or discoloured plastic

Something has already overheated. What you can see from the front is rarely all of the damage.

Turn it off at the board and call 0411 498 916

What goes into a new board

  • A main switch that shuts off the whole installation in one movement
  • Safety switch protection on every circuit that needs it — in practice, nearly all of them
  • Separate breakers or RCBOs per circuit, so a fault in the bathroom doesn’t take the fridge with it
  • Clear labelling the next electrician — or you, at 10pm — can actually follow
  • Spare positions for whatever you add over the next decade
  • Surge protection where it’s warranted, particularly if the house runs automation or a lot of electronics

With the board open we also test the main earth and the MEN link. In older terraces and blocks of flats, that is often where the real problem turns out to be.

Two local wrinkles. In heritage conservation areas — much of Paddington and Woollahra, and parts of Waverley and Randwick — the meter box on the front façade often can’t simply be moved, so the new board is planned around where it’s allowed to sit. And in apartment buildings, the board inside your unit is generally yours while the meters and mains that feed it belong to the owners corporation; we’ll tell you which side of that line any problem sits on.

What happens on the day

1

We look at what’s there

The board, the meter panel, the earthing, the supply, and how many circuits the household genuinely needs now.

2

You get a fixed price

Including any remedial work we can see, so the number you approve is the number you pay.

3

Power off, old board out, new board in

Most houses and apartments are done in a day, and you’ll know the expected off-time beforehand. If we need the meter room or a riser cupboard in a strata building, we arrange that access in advance.

4

Tested, labelled and certified

Every circuit tested and labelled, a CCEW issued, and our 25-year workmanship warranty on the job.

Switchboard upgrade questions

How long will the power be off?

For a typical home or apartment board, plan on most of the working day without power. We give you a realistic window in advance so you can sort out the fridge, the freezer and anyone working from home.

Is an old switchboard illegal?

No — there’s no rule that forces you to replace a working board because of its age. But new and altered circuits must be RCD protected, so in practice almost any real electrical work on an old board brings the upgrade with it.

Can you add safety switches to the board I have?

Sometimes. If the board is reasonably modern with space and a suitable layout, RCDs can go in without replacing it. On a ceramic fuse board there’s nowhere to fit them, so the board has to change. We’ll tell you plainly which you’ve got.

I live in an apartment. Do I need strata approval?

Usually not for the board that serves only your unit — it sits within your lot. If the work needs access to a common-property cupboard, riser or meter room, the building or strata manager will generally want notice. Anything on the meter side is the owners corporation’s to organise.

Our terrace is in a heritage conservation area. Does that change things?

It can affect where a meter box or external board is allowed to go, and moving one on a front façade may involve council. Replacing a board in its existing position is rarely a problem. We plan the work so you aren’t caught out halfway through.

Do you deal with Ausgrid?

For a like-for-like board replacement there’s nothing to arrange. If the supply itself needs changing — moving to three phase or increasing capacity — that involves Ausgrid, and we handle that side.

What if you find something else once the old board is out?

In older homes it does happen. We stop, show you, and price it before touching it. Nothing appears on the invoice that you haven’t agreed to.

Will I get a compliance certificate?

Yes. Every switchboard upgrade gets a Certificate of Compliance for Electrical Work, as NSW requires.

What a switchboard upgrade costs

The new board is the predictable part. What’s behind the old one is what moves the price.

The jobPrice
Safety switches added to an existing modern boardWhere the board is in good order and has roomfrom $350
Standard single-phase switchboard upgradeMost houses and apartments. New enclosure, main switch, RCBOs on every circuit, labelling, full testing and a CCEW$1,500 – $3,500
Three-phase board, or a board needing Level 2 service workLarger homes, or where the service mains or meter position need attention$3,500 – $6,500
Asbestos-backed meter panel removalOften found behind the meters in older houses and flats. Licensed removal, charged on top of the board$500 – $1,500

These are indicative market ranges for Sydney in 2026, not a quote. What you pay depends on your switchboard, access and what we find. We confirm a fixed price before starting, and it doesn’t move.

What customers say

★★★★★

Fantastic service! Friendly, efficient and well priced. Highly recommend. Thank you for swiftly fixing our switches.

Lynette Haines · August 2025
★★★★★

Jason onsite quickly and completed the work on the spot, giving us a good price and was very polite. Would highly recommend.

Hans Banneck · March 2026
★★★★★

Jason solved a really complex problem for our house with excellent professionalism and workmanship. Highly recommend, would def work with him again. On time delivery and within budget.

Raghav Murali-Ganesh · May 2026

These are Google reviews for Cync Electrical & Automation. 5.0 from 20 reviews. — see the profile

Switchboards we’ve replaced

Want your switchboard checked?

Send us a photo of the board and we’ll tell you where you stand. Or call 0411 498 916.

No obligation. We’ll review it and get back to you.